High Quality Electrocoagulation Wastewater Treatment for Power Plant / electro flocculator
1 sets
MOQ
as per model
Price
High Quality Electrocoagulation Wastewater Treatment for Power Plant / electro flocculator
Features Gallery Product Description Request A Quote
Features
Basic Infomation
Place of Origin: China
Brand Name: Loren
Certification: CE, ISO ,CCC,
Model Number: LEC series
Payment & Shipping Terms
Packaging Details: Standard export packing
Delivery Time: within 30 days
Payment Terms: T/T, L/C, D/P, Western Union
Supply Ability: 50 sets per month
Specifications
Cod Removal Ratio: 30%-80%
Oil And TSS Removal: Over 90% With 1 Ppm
Turbidity Reduced: Can Reach Below 3 NTU
SiO2 Wipe Out: 70%-90% Compare Other 30-40%
Heavy Metal Ion Reduce: 80%-95%
Chroma,(8) Bacteria, Viruses Reduced: Over 80%
Free Maintenance: For 2 Years
Little: Investment
No: Operating Charge And Little Maintenance Cost
Small: Footprint
Run: Simplely , Easily And Automatically
Little: Sludge Happened
Fast And Flexible: Design , Make And Service
Product Description

The electrocoagulation method can be used alone or in combination with other treatment methods, such as pretreatment method, which can improve the biodegradability of wastewater; generally for refractory organic wastewater, such as pharmaceutical, chemical, fuel industry wastewater and contains refractory treatment The toxic substances have a good treatment effect. Electro-flocculation is mainly used to remove heavy metals, suspended solids and emulsified organic matter in wastewater. It has been widely used in petroleum and petrochemical industries, electroplating industry,non-ferrous metal smelting industry and ship bottom sewage treatment. The treatment effect of the process on pollutants is shown in the following table:

High Quality Electrocoagulation Wastewater Treatment for Power Plant / electro flocculator 0

 

Application of electroflocculation in treatment of high concentration organic wastewater

When the high-concentration biochemical and non-biochemical organic wastewater is treated by the traditional process, the traditional process is used, the process is long, the operation cost is high, the load is high, and the effect is not obvious; the electroflocculation has been successfully used for such wastewater treatment, Under the action of electric charge, biochemical and non- biochemical organic matter directly breaks the molecular bond and degrades COD. For example, high-concentration organic wastewater in slaughtering and aquaculture, high-concentration wastewater in food plants, alkane-containing wastewater in petroleum industry, textile printing and dyeing wastewater, etc.

 

Application of electroflocculation in treatment of high ammonia nitrogen wastewater

In the treatment of high ammonia nitrogen wastewater, electroflocculation also has a good treatment effect, which has been applied to the treatment of garbage leakage.

 

Application of electroflocculation in the treatment of electroplating wastewater (including heavy metals)

 

Electro-flocculation in the treatment and reuse of electroplating wastewater can overcome the problems that are difficult to solve by chemical treatment. It can not only effectively remove heavy metal ions in electroplating wastewater, but also reduce the salt content in water, so that the treated water can be recycled and reused. Process. Electroplating wastewater treated by electroflocculation can achieve the following treatment effects: Cr<0.001, removal rate up to 100%; Ni<0.005 removal rate up to 100%; Zn<0.062 removal rate up to 57%.

 

Application of electroflocculation in the treatment of fluorine- containing wastewater

In some developing countries, such as China, Egypt, India, etc., fluorosis is an endemic disease with a long-term comparison. Therefore, the defluoridation problem of drinking water has become a popular direction. The methods of removing fluorine include: lime precipitation method, coagulation sedimentation method, adsorption and ion exchange method, electrocoagulation method, electrodialysis method, reverse osmosis method, etc.

  Electrocoagulation is a more competitive method.

 

Application of electroflocculation in dye (high chroma) wastewater treatment

Dye wastewater has the characteristics of high COD, high chroma, high salt content, and difficult organic degradation of organic matter. In the past, it has been generally treated by a combination of physicochemical methods and biological methods. However, due to the complicated drainage composition, the handling difficulty is still large. With the development of electroflocculation technology, electrocoagulation treatment of dye wastewater has the advantages of small equipment, small land occupation, simple operation management, high COD removal rate and good decolorization effect.

 

Application of electroflocculation in wastewater treatment of shipyards

(including emulsified oil and heavy metals) Electroflocculation has a unique effect in the treatment of oil latex, SS, organic matter. Can be widely used in petrochemical, paint dyes, pigments and other wastewater, car wash wastewater, oil field wastewater and other fields.

High Quality Electrocoagulation Wastewater Treatment for Power Plant / electro flocculator 1

 

Technical characteristics of the equipment

 

Outstanding Characteristic 

  • Low investment costs
  • Low operating costs
  • Low maintenance and repair costs
  • No need to add any chemicals
  • Small footprint
  • Simple operation and high degree of automation
  • Short processing time and high processing efficiency
  • Adapt to a wide range of wastewater, can handle a variety of pollutants
  • Equipment processing produces less sludge and sludge
  • High Quality Electrocoagulation Wastewater Treatment for Power Plant / electro flocculator 2
  • Equipment model specifications and main technical parameters
Model Capacity Dimension Voltage Currency Power Tank Pole plate
LEC-01 1 1.5*1.0*1.5m <36V <10mA 3KW Steel

 

Titanium aluminum nickel iron graphite composite

LEC-03 3 1.8*1.2*1.5m <36V <10mA 6KW Steel
LEC-05 5 2.0*1.3*2.5m <36V <10mA 9KW Steel
LEC-10 10 3.0*2.2*2.5m <36V <10mA 12KW Steel
LEC-15 15 3.5*2.2*2.5m <36V <10mA 15KW Steel
LEC-20 20 4.0*2.2*2.5m <36V <10mA 24KW Steel
LEC-30 30 5.0*2.4*2.5m <36V <10mA 32KW Steel
LEC-50 50 8.0*2.4*3.0m <36V <10mA 36KW Steel

 

 

 

Equipment operating costs

 

Power consumption: According to different water treatment requirements, the electricity consumption per ton of water treated is 0.1-1.5kWh.

Plate loss: According to different water treatment requirements, the cost of plate consumption is 0.01-0.03 CN RMB / ton of water.

Electric flocculation operation cost: 0.06 - 0.78 CN RMB / ton of water (electricity price is 0.5 CN RMB / kW)

 

Equipment operation instructions

 

Installation method

The electric flocculation can be installed at the location near the treatment site, and the power control cabinet should be placed in the drying equipment room. If there are special explosion-proof requirements, it needs to be explained in advance.

 

Method of operation

The equipment is a continuous automatic operation mode, and no special care is required. The water inlet is provided with a flow meter, and the flow rate can be controlled by the valve. The water is pressurized by the pump into other processing systems, or directly discharged, and the equipment discharge can be set to manual or automatic control according to requirements.

High Quality Electrocoagulation Wastewater Treatment for Power Plant / electro flocculator 3

 

Precautions:

  1. When the equipment is used, it needs to be turned on and then turned on. If the equipment is not in use, the equipment cannot be energized to avoid danger and equipment damage.
  2. Do not arbitrarily power off when the equipment is working through water.
  3. Do not touch the voltage output when powering up to avoid danger.
  4. Keep the heat sink well ventilated when the device is powered.
  5. The electrical parts must not be watered or wrapped in plastic cloth or the like.
  6. The equipment must be shut down before servicing.
  7. If the subsequent process or equipment has been fouled, the treated process or equipment should be drained once every 2 hours, no less than 3 minutes each time; and the dirt should be cleaned regularly to prevent the residue from clogging the equipment and causing an accident.
  8. Do not rub hard when loading or unloading equipment.
  9. High Quality Electrocoagulation Wastewater Treatment for Power Plant / electro flocculator 4
Recommended Products
Get in touch with us
Tel : 8613952466865
Fax : 86-510-86086452
Characters Remaining(20/3000)